ICM Controls ICM495-30A 30 Amp Disconnect with Internal Surge Protection (Fused)
Ac Spare Parts Supplier in Guangzhou China
中国烟台空调备件供应商
ICM Controls supplier in China.
We are the leading Wholesaler, Distributor, Supplier of ICM Controls ICM495-30A 30 Amp Disconnect with Internal Surge Protection (Fused) in Yiwu China.
ICM Controls Manufacturer & factory in China.
我们是领先的批发商、分销商、供应商 ICM Controls ICM495-30A 30 Amp Disconnect with Internal Surge Protection (Fused) 在中国义乌。
ICM Controls ICM495-30A 30 Amp Disconnect with Internal Surge Protection (Fused)
- UL Listed Electrical Disconnect including both enclosure & surge protector
- 120VAC single-phase, 240VAC split-phase
- Features an internal surge protective device
- Maximum Surge Current Rating of 100kA
- Highest UL rating for nominal discharge current (in 20kA), for increased longevity & durability of the SPD
- Constructed with 2 high-quality thermally protected MOV’s (TFMOV)
- Completely factory wired for quick and easy installation
- NEMA type 3R rated powder coated metal enclosure for indoor/outdoor use
- Fully accessible mounting holes, no disassembling required
- Braided strap thoroughly grounding both the enclosure and cover
- LED indicator light showing when surge protection is operational
- 30A Fused & 60A non-fused models available
- Made in the USA
- Limited lifetime product, up to a 3-year $10,000 connected equipment warranty
Protects Against:
-
Lightning strikes
-
Power outages & recoveries
-
Downed power lines
-
Startup of larger equipment
-
Equipment failure
-
Short circuits and more…
SPECIFICATIONS:
- Service Voltage: Split Phase 240 VAC; 30A at -40°C min. and 25°C max., 240 VAC; 25A at -40°C min. and 55°C max., 240VAC; 60A at -40°C min. and 55°C max.
- Short Circuit Current Rating (SCCR): 10 kA
- Maximum Surge Current: 100 kA (single event)
- Nominal Discharge Current (In): 20 kA (15 multiple events)
- SPD Type: Type 2 applications only
- Surge Protection Technology: TFMOV
- Protection Mode: L1-L2, L1-G, L2-G
- Maximum Continuous Operation Voltage (MCOV): L-L: 300 VAC, L-G: 150 VAC
- VPR (Vpk): Mode: L-L = 1200, L-N = 700
- Input Power Frequency: 50/60 Hz
- Diagnostics: Green LED indicates surge protection present
- Enclosure Rating: NEMA/Type 3R metal enclosure for outdoor and indoor installation
- Installation Point: Located within sight of the motor controller/equipment
- Dimensions: 9.0” L x 5.25” W x 2.50” D
- Operating Temperature: -40°F to 131°F (-40°C to 55°C)
- Operating Humidity: Less than 85%, non-condensing
- Operating Altitude: Less than 2000 meters
- Agency Certification and Approvals: ANSI/UL1449 5th Edition cULus Listed Device
REPLACES:
All standard disconnect boxes rated for equal voltage and current configurations:
30A – MARS: 83916, RectorSeal: 96417 w/ RSH-50
60A – MARS: 83915, RectorSeal: 96419 w/ RSH-50
Sell Sheet
Installation Guide


Reviews
There are no reviews yet.